Here’s the “hit parade” of error codes you’ll see most on Alliance Laundry Systems commercial washers — Speed Queen / Huebsch / UniMac — especially with Quantum/Quantum Gold/Insight-era controls. The same codes and fixes apply across the three badges because the control platforms are shared. I’ll give you the plain meaning + the field-fast diagnosis/fix.
1) Fill / water-level faults
E_FL / E:FL / Er, FL — Fill Error
Meaning: Washer didn’t reach the required water level within the maximum fill time. sqinsights.zendesk.com+2Laundry Nation+2
Most common causes
-
Hot/cold supply valves not fully open or low building pressure
-
Inlet screens plugged with grit/scale
-
Failed inlet valve coil or loose spade
-
Level/pressure tube issue (air leak, kink, soap gunk in air trap)
Fix / diagnosis
-
Verify supply & pressure at wall. Open valves fully; quick hose-bucket test if needed.
-
Clean inlet screens. Remove hoses, pull/flush screens at the valve body.
-
Valve actuation test. In diagnostics, command hot then cold fill; listen for click + verify flow.
-
Check level system. Inspect pressure hose from tub → sensor for cracks/kinks/water inside; clear air trap.
Er, OF / E_OF — Overflow
Meaning: Water level rose to overflow threshold. SmartHomeBit+1
Most common causes
-
Fill valve stuck open (debris in seat)
-
Pressure hose fell off / punctured / air trap blocked
-
Level sensor drift/failure
Fix / diagnosis
-
Shut building water off while code is showing.
-
If level keeps rising → inlet valve stuck open → replace/clean valve.
-
If level stops → level sensing problem.
-
-
Inspect/clean air trap & pressure tube; confirm airtight fit to sensor.
E_Pr / Er, Pr — Pressure Switch Sequence Error
Meaning: Control sees pressure switch states out of expected order. Laundry Nation+1
Most common causes
-
Pressure tube partially blocked with detergent sludge
-
Air leak in tube/air bell
-
Failed pressure switch
Fix / diagnosis
-
Remove/clean pressure hose + air trap.
-
Leak-check hose connections.
-
If error returns with clean, tight tube → replace pressure switch/sensor.
2) Drain faults
E_dr / E:dr / Er, dr — Drain Error
Meaning: Max drain time exceeded or water still detected at end of drain/spin. sqinsights.zendesk.com+1
Most common causes
-
Coin trap/sump or pump inlet clogged
-
Drain hose kinked / standpipe restricted or backing up
-
Weak/failing drain pump
-
Pressure tube blocked so control “thinks” water remains
Fix / diagnosis
-
Run drain test in diagnostics — should be strong steady outflow.
-
Clean coin trap/sump and check impeller for debris.
-
Inspect hose + standpipe (height, kinks, clogs, slow site drain).
-
If pump has voltage but weak/no flow → replace pump.
3) Door / interlock faults
E_dL / E_DL / Er, dL — Door Lock Error
Meaning: Door didn’t lock when commanded or lock feedback doesn’t match. How To Fix It+1
Most common causes
-
Door sag/striker not entering lock fully
-
Failed lock wax motor/solenoid
-
Harness break at hinge/front panel area
Fix / diagnosis
-
Mechanical first: Confirm door alignment and striker depth.
-
Lock test: In diagnostics, energize lock and verify “locked” input changes.
-
Meter lock coil/switches and inspect connectors for heat/corrosion.
-
Repair wiring or replace lock.
door / dor / Er, do — Door Open During Cycle
Meaning: Door-closed input dropped mid-cycle. huebschcommand.zendesk.com+1
Fix
-
Reseat/align door, check door-closed switch and wiring.
-
If switch is intermittent → replace switch/lock assembly.
4) Balance / load faults
Er, ub / E_ub — Unbalanced Load
Meaning: Excess vibration; final spin canceled. Authorized Service
Most common causes
-
Overloading or one heavy item
-
Worn shocks/springs
-
Machine not level / weak base
Fix / diagnosis
-
Rebalance load; confirm correct load size practices.
-
Verify machine level & anchoring.
-
Inspect suspension (shocks leaking, springs stretched/broken).
-
Replace worn suspension parts if recurring.
5) Heating / temperature sensor faults (for heated models)
E_ht / Er, Ht — Heater Error
Meaning: Water temp didn’t rise as expected, or heater circuit fault. Laundry Nation
E_OP — Open Temp Sensor / E_SH — Shorted Temp Sensor
Meaning: NTC/RTD temperature sensor open or short. huebschcommand.zendesk.com+1
Fix / diagnosis (same family)
-
Check heater resistance + insulation-to-ground.
-
Verify heater relay/contactor output during heat step.
-
Test temp sensor resistance vs temp chart; clean/repair connectors.
-
If wiring/sensor good and no heat output → control/relay fault.
6) Vended / security faults you’ll see in laundromats
Alrn / ALrn — Break-In Alarm
Meaning: Service door or coin vault switch triggered. sqinsights.zendesk.com+1
Fix
-
Inspect/adjust vault and service-door switches; check for bent brackets or tampering.
E rr / Err — Coin Error
Meaning: Invalid coin pulse or coin sensor not reading. sqinsights.zendesk.com+1
Fix
-
Clear coin drop obstruction, verify coin switch/sensor alignment and harness.
Quick tech-friendly diagnostic rule
-
E_FL / E_OF / E_Pr → water-in / level system (valves, screens, pressure tube, calibration).
-
E_dr → drain path (trap, pump, hose, site drain).
-
E_dL / door → door lock + wiring + alignment.
-
E_ub → load practice or suspension/leveling.
-
E_ht / E_OP / E_SH → heater or temp sensing.
-
Alrn / Err → vend/security inputs.